Check the datasheet for further details.
This module interfaces with the DHT22 (also DHT21, DHT22, DHT33, DHT44, RHT01, RHT02, RHT03, RHT04, RHT05, AM2301, AM2302, AM2303 and HM2301), an inexpensive temperature and relative humidity sensor similar to the DHT11, but with higher accuracy and wider range.
Key Specifications:
Temperature Range | -40~80 C |
Temp. Accuracy | +/- 0.5C |
Humidity Range | 0 ~ 100% |
Humidity Accuracy | +/- 2% |
The module will retry if it doesn't get any response, or if other sanity checks fail. If it fails 10 times in a row, the callback will be called with an error (see below), indicating a likely problem with the sensor or wiring. The DHT22 is much more reliable than the DHT11, and it rarely fails to provide data, however, it is still important to perform your own sanity checks on the data returned.
From left to right when part is viewed from the front (the side with the ventilation holes) with pins pointing down. (The DHT22 has no pin markings).
IMPORTANT: Be sure to get the polarity right! If connected backwards, it will ruin the DHT22.
Device Pin | Espruino |
---|---|
1 (Vcc) | 3.3 |
2 (S) | Any GPIO |
3 (NC) | N/C* |
4 (GND) | GND |
Note: There are reports of DHT22s on the market where pins 3 and 4 are reversed. Meanwhile, app notes sometimes depict pins 2 and 3 tied together.
Call require("DHT22").connect(pin)
to get a DHT22 object. To read the sensor, the read
method is called with a single argument, the function that is called when the read is complete. This function is called with an object containing two properties, temp
and rh
. Temperature is in °C, RH is in %.
For example:
var dht = require("DHT22").connect(C11);
dht.read(function (a) {console.log("Temp is "+a.temp.toString()+" and RH is "+a.rh.toString());});
Returns -1
for the temperature and humidity (and err:true
) if no data is received. An extra checksumError
field contains extra information about the type of the failure:
If no data received at all: {"temp": -1, "rh": -1, err : true, "checksumError": false}
.
If some data received, but the checksum is invalid, or timed out: {"temp": -1, "rh": -1, err : true, "checksumError": true}
In all cases, a field called raw
is present which contains the raw data received, as a string of 1
and 0
characters.
Note: You can also supply a second argument which is the number of retries if there is an error. The default is 10. Collecting period should be : >2 seconds.
DHT22 parts and modules can be purchased from many places:
This page is auto-generated from GitHub. If you see any mistakes or have suggestions, please let us know.